{"id":163,"date":"2017-05-09T12:09:38","date_gmt":"2017-05-09T15:09:38","guid":{"rendered":"https:\/\/sites.ifi.unicamp.br\/padilha\/?page_id=163"},"modified":"2017-05-11T11:22:04","modified_gmt":"2017-05-11T14:22:04","slug":"laboratory","status":"publish","type":"page","link":"https:\/\/sites.ifi.unicamp.br\/padilha\/laboratory\/","title":{"rendered":"Laboratory"},"content":{"rendered":"<p><span style=\"font-size: 10pt\">The USL is part of the <a href=\"https:\/\/sites.ifi.unicamp.br\/gfurco\" target=\"_blank\" rel=\"noopener noreferrer\">Group of Ultrafast Phenomena and Optical Communications<\/a> at the &#8220;Gleb Wataghin&#8221; Institute of Physics. Currently, the lab has an 650 square feet space divided in two laboratories. Shortly these labs will move to a new building to a 1200 square feet space, which will allow further development of the experiments.&nbsp;<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 12pt;color: #0000ff\"><strong>Laser Facilities<\/strong><\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 10pt\"><strong><img decoding=\"async\" class=\"wp-image-174 alignleft\" src=\"https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/Imagem11-300x225.jpg\" alt=\"\" width=\"245\" height=\"183\" srcset=\"https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/Imagem11-300x225.jpg 300w, https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/Imagem11-768x576.jpg 768w, https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/Imagem11-1024x768.jpg 1024w, https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/Imagem11.jpg 1500w\" sizes=\"(max-width: 245px) 100vw, 245px\" \/><\/strong><\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 10pt\"><strong>Amplified Ti:sapphire laser system <\/strong><\/span>operating at 1 kHz and 800 nm, delivering pulses of about 80 fs.<span style=\"font-size: 8pt\"><br \/>\n<\/span><\/p>\n<p><span style=\"font-size: 10pt\"><strong>Femtosecond OPA<\/strong> <\/span>covering the range from 400 nm to 2600 nm&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<br \/>\n<img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-176 alignright\" src=\"https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/Imagem12-1-300x193.jpg\" alt=\"\" width=\"300\" height=\"193\" srcset=\"https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/Imagem12-1-300x193.jpg 300w, https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/Imagem12-1-768x495.jpg 768w, https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/Imagem12-1.jpg 822w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 10pt\"><strong>Amplified&nbsp;Yb fiber-based laser system <\/strong><\/span>operating at 200 kHz and 1040 nm with pulses of the order of 300 fs.<\/p>\n<p><span style=\"font-size: 10pt\"><strong>Three ultrafast NOPAs<\/strong><\/span> covering the range from 300 nm to 1600 nm, and delivering pulses as short as 20 fs.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong><span style=\"color: #0000ff\"><span style=\"font-size: 12pt\">Data <\/span><span style=\"font-size: 16px\">Acquisition<\/span><span style=\"font-size: 12pt\">&nbsp;Facilities<\/span><\/span><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" class=\" wp-image-177 alignleft\" src=\"https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/Imagem13-300x225.jpg\" alt=\"\" width=\"257\" height=\"193\" srcset=\"https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/Imagem13-300x225.jpg 300w, https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/Imagem13-768x577.jpg 768w, https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/Imagem13-1024x769.jpg 1024w, https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/Imagem13.jpg 1476w\" sizes=\"(max-width: 257px) 100vw, 257px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 10pt\"><strong>Two-Photon Photoluminescence System<\/strong><span style=\"font-size: 8pt\">&nbsp;<\/span><\/span><\/p>\n<p>This home-built two-photon photoluminescence system allows the detection of two-photon excited emission, even from low quantum yield colloidal samples, in the range from 400 nm to 900 nm.&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-179 alignright\" src=\"https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/IMG_9650-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/IMG_9650-300x225.jpg 300w, https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/IMG_9650-768x576.jpg 768w, https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/IMG_9650-1024x768.jpg 1024w, https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/IMG_9650.jpg 2016w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 10pt\"><strong>Time Correlated Single Photon Counting<\/strong><span style=\"font-size: 8pt\">&nbsp;<\/span><\/span><\/p>\n<p>This Horiba\/Jobin Yvon Nanolog system allows for analysis of the photoluminescence with temporal and spectral resolution. This system operates from 350 nm to 950 nm and covers up to 4 microseconds with a resolution of 25 ps.&nbsp;<\/p>\n<p>This system is also connected to a <strong>visible CCD<\/strong> and a <strong>NIR InGaAs<\/strong> array for steady state photoluminescence characterization in a range from 350 nm to 1700 nm.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: left\"><strong><span style=\"color: #0000ff\"><span style=\"font-size: 16px\">Other<\/span><span style=\"font-size: 12pt\">&nbsp;Facilities<\/span><\/span><\/strong><\/p>\n<p style=\"text-align: left\">&nbsp;<\/p>\n<p style=\"text-align: left\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-181 alignleft\" src=\"https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/IMG_9651-1-e1494365754727-225x300.jpg\" alt=\"\" width=\"185\" height=\"247\" srcset=\"https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/IMG_9651-1-e1494365754727-225x300.jpg 225w, https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/IMG_9651-1-e1494365754727-768x1024.jpg 768w, https:\/\/sites.ifi.unicamp.br\/padilha\/files\/2017\/05\/IMG_9651-1-e1494365754727.jpg 1512w\" sizes=\"(max-width: 185px) 100vw, 185px\" \/><\/p>\n<p style=\"text-align: right\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: right\"><span style=\"font-size: 10pt\"><strong>Fume hood for colloidal samples preparation<\/strong><\/span><\/p>\n<p style=\"text-align: right\"><span style=\"font-size: 10pt\"><strong>Confocal Microscope for Nonlinear Optical Imaging<\/strong><\/span><\/p>\n<p style=\"text-align: right\"><span style=\"font-size: 10pt\"><strong>Cryogenics systems<\/strong><\/span><\/p>\n<p style=\"text-align: right\"><span style=\"font-size: 10pt\"><strong>Ultra-precise computer controlled delay stages<\/strong><\/span><\/p>\n<p style=\"text-align: right\"><span style=\"font-size: 10pt\"><strong>Several ultrafast and nonlinear spectroscopy techniques<\/strong><\/span><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The USL is part of the Group of Ultrafast Phenomena and Optical Communications at the &#8220;Gleb Wataghin&#8221; Institute of Physics. Currently, the lab has an 650 square feet space divided in two laboratories. Shortly these labs will move to a new building to a 1200 square feet space, which will allow further development of the &hellip; <\/p>\n<p><a class=\"more-link btn\" href=\"https:\/\/sites.ifi.unicamp.br\/padilha\/laboratory\/\">Continue reading<\/a><\/p>\n","protected":false},"author":166,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-163","page","type-page","status-publish","hentry","nodate","item-wrap"],"_links":{"self":[{"href":"https:\/\/sites.ifi.unicamp.br\/padilha\/wp-json\/wp\/v2\/pages\/163","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sites.ifi.unicamp.br\/padilha\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/sites.ifi.unicamp.br\/padilha\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/sites.ifi.unicamp.br\/padilha\/wp-json\/wp\/v2\/users\/166"}],"replies":[{"embeddable":true,"href":"https:\/\/sites.ifi.unicamp.br\/padilha\/wp-json\/wp\/v2\/comments?post=163"}],"version-history":[{"count":7,"href":"https:\/\/sites.ifi.unicamp.br\/padilha\/wp-json\/wp\/v2\/pages\/163\/revisions"}],"predecessor-version":[{"id":263,"href":"https:\/\/sites.ifi.unicamp.br\/padilha\/wp-json\/wp\/v2\/pages\/163\/revisions\/263"}],"wp:attachment":[{"href":"https:\/\/sites.ifi.unicamp.br\/padilha\/wp-json\/wp\/v2\/media?parent=163"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}